Chapter 3 - Additional Features
User Guide 219
Serial Settings
This feature controls the speed, data size, parity, and stop bits of all ports. It also sets the flow
control to hardware, software, or none; the DCD signal; and tty settings after a socket connec-
tion to that serial port is established.
Parameters Involved and Passed Values
Terminal Settings involve the following parameters (the first four are physical parameters):
all.speed The speed for all ports. Default value: 9600.
all.datasize The data size for all ports. Default value: 8.
all.stopbits The number of stop bits for all ports. Default value: 1.
all.parity The parity for all ports. Default value: none.
all.flow This sets the flow control to hardware, software, or none.
Default value: none.
all.dcd DCD signal (sets the tty parameter CLOCAL). Valid values
are 0 or 1. If all.dcd=0, a connection request will be
accepted regardless of the DCD signal and the connection
will not be closed if the DCD signal is set to DOWN. If
all.dcd=1 a connection request will be accepted only if the
DCD signal is UP and the connection will be closed if the
DCD signal is set to DOWN. Default value: 0.
Commenti su questo manuale